Description:
When Reverse Engineering from script, as soon as the Reverse Engineer begins, the below error message is received:
"A processing error has occurred".
Syntax Error - Line 0, Offset 0 ÿþC
Advisories Log shows:
RES-1: Syntax Error - Line 0, Offset 0 ÿþC
Solution:
This is most likely due to the script file being saved in UTF format, which is not supported in erwin. To resolve the issue, open the script file in a Notepad and save the file in ANSI format:
Comments
0 comments
Please sign in to leave a comment.